|
|
|
 |
SANbox 9000 |
 |
|
The Enterprise-Class Advantage – for every business! Finally, the scalability, resiliency, manageability and security benefits of a modular chassis switch are available without the high price of a traditional director. Start small and grow large while you reduce TCO with the industry’s first Customer Replaceable Unit (CRU) components, smallest footprint, most flexible rack-mount options and leading power/cooling efficiency. | |
|
|
|
|
|
|
| |
| Designed to the Core™ for Open Systems |
|
Changing business requirements at many of today’s best companies are driving the need for the scalability, resiliency, and manageability provided by modular chassis-based SAN switches. As new and unpredictable demands spring up every quarter, these companies require the flexibility to modify and expand their server/storage infrastructure frequently without impacting production environments. In addition, as the mission-critical role of data continues to grow, more businesses than ever must guarantee iron-clad security while providing a high degree of control and monitoring.
Until now, the robust performance, rapid deployment potential, and "pay as you grow" budgeting advantages of Fibre Channel chassis switches have been available only in the form of expensive Director appliances targeted primarily at mainframe customers. IT managers with high-port-count open systems SANs who are unwilling to pay a premium for unused Director features (such as FICON support) have been forced to purchase complicated meshes of smaller switches, or very large fixed-port units – both of which offer high port counts, but much less flexibility, fault tolerance, and overall system control.
QLogic now provides a new class of core switch, representing a sane alternative to quarter-million dollar Directors and large, less resilient fixed-port switches. The SANbox 9000 is Designed to the Core for cost-sensitive, business-critical, open-system environments that require high port and performance, with support for 99.999% available solutions.
| | |
|
|
|
|
|
| |
| Scalability |
- 16 to 128 ports in a single 4U chassis
- 256 ports in a dual-chassis 8U HyperStack™
- Mix and match Fibre Channel I/O blades
- 8Gb or 4Gb blades for server/storage connections (16 ports each)
- 10Gb blades for auto-trunking links to other switches (4 ports each)
- Intelligent Storage Router Modules: iSCSI for connecting low-cost servers and FCIP for replicating data across a WAN.
|
| Fault-Tolerance |
- Dual CPU option – True director-class redundancy with failover is now affordable for open system SANs. No large edge switch can compare!
- Hot-swappable I/O blades – Easy, non-disruptive expansion and maintenance
- Redundant, hot-swappable power supplies and fans
|
| Low Cost of Ownership |
- Pricing begins well under $100K
- 16-port entry point
- More standard features at no charge, fewer software licenses
- Customer Replaceable Units (CRUs) ensure simplicity, economy
- Lower power consumption, smaller rack space footprint, lower weight
|
| Powerful Included Software |
- QuickTools™ gets you up and running in minutes.
- Enterprise Fabric Suite™ 2007 helps you set up, monitor, tune, troubleshoot and service an unlimited number of large fabrics.
- Adaptive Trunking, RSCN suppression, Drag-and-drop Zoning Wizard, Extended Distance and more at no extra charge
- Advanced Fabric Security – Protect your data with the right mix of easy-to-implement features:
- User security
- Connection security
- Device security
|
| | | |
|
|
|
|
|
| |
|
Fabric Specifications |
| Fibre Channel Protocols |
- Physical Interface (FC-PI-3)
- Line Services (FC-LS)
- Framing & Signaling (FC-FS-2)
- Generic Services (FC-GS/FC-GS-2/FC-GS-3/FCGS- 4/FC-GS-5)
- Switch Fabric (FC-SW-2/FC-SW-3/FC-SW-4), except for enhanced zoning
- Arbitrated Loop Rev. 4.6 (FC-AL)
- Arbitrated Loop-2 Rev. 7.0 (FC-AL-2)
- Fibre Loop Attachment (FC-FLA)
- Tape Technical Report (FC-Tape)
- Virtual Interface Architecture Mapping (FC-VI)
- Fabric Element MIB Specification (RFC 2837)
- Fibre Alliance MIB Specification (Version 4.0)
- Methodologies for Interconnects (FC-MI-2)
- Device Attach (FC-DA)
- Security Protocols (FC-SP)
|
| Fibre Channel Classes of Service |
|
Class 2, Class 3, and Class F (inter-switch frames) connectionless Fibre Channel protocol support |
| Modes of Operation |
- Fabric
- Public loop
- Broadcast
|
| Performance Features |
| Fabric Port Speed |
- 4Gb I/O Blade (SB9004-4G) @ 1.0625, 2.125, and 4.250 Gbps
- Auto sensing of 1, 2, and 4 Gbps port speeds
- Optionally programmable to fixed port speed
- 8Gb I/O Blade (SB9004-8G) @ 1.0625, 2.125, 4.250, and 8.50 Gbps
- Auto sensing of 1, 2, 4 and 8 Gbps port speeds
- Optionally programmable to fixed port speed
- FC10G4 I/O Blades @ 12.75 Gbps
|
| FC Fabric Latency (Best Case) |
- 4Gb I/O blade (SB9004-4G): <0.3μsec @ 4 Gbps
- 8Gb I/O blade (SB9008-8G): <0.2μsec @ 8 Gbps
- 10Gb I/O blade (SB9010-10G): <0.2μsec @ 10 Gbps
|
| FC Fabric Point-to-Point Bandwidth |
- 212MB/s Full-Duplex on 1Gb ports
- 424MB/s Full-Duplex on 2Gb ports
- 850MB/s Full-Duplex on 4Gb ports
- 1700MB/s Full-Duplex on 8Gb ports
- 2550MB/s Full-Duplex on 10Gb ports
|
| System Bandwidth |
- Backplane switching capacity
- SB9100 Model – 408 Gbps, full-duplex
- SB9200 Model – 816 Gbps, full-duplex
- 2X SB9200 HyperStack – 1632 Gbps, fullduplex
- Non-blocking HyperStack architecture
- Local switching capacity
- SB9100, 4Gb blades – 1088 Gbps
- SB9100, 8Gb blades – 2176 Gbps
- SB9200. 4Gb blades – 2176 Gbps
- SB9200, 8Gb blades – 4352 Gbps
|
| Maximum Frame Sizes |
- 2148 bytes (2112 byte payload)
- In-order delivery assured within OX-ID
|
| Per-port Buffering |
- ASIC-embedded memory (non-shared)
- Each port has a guaranteed 16-credit zero wait state buffer for full performance up to
13km @ 2Gb and 2Km @ 10Gb
- Buffer credit donor support via software GUI wizard to extend distance with full performance
|
| Inter-Switch Link (ISL) Trunking |
- Supports aggregation of up to 128 ISLs in one or more trunks between multiple switches in
any port speed combination and across multiple I/O Blades
- 10Gb recommended to maximize number of usable 4/2/1Gb Server/Storage ports on
both SANbox 5000 Series and 9000 Series switches
- Switch-On-Exchange (SOE) mode for dynamic ISL trunk load balancing to maximize throughput
- Assured in-order delivery of frames in all multi-switch and multi-ISL trunked configurations
- Adaptive Trunking to improve efficiency via optimal routing across multiple trunk groups
- Intelligent Path Selection (IPS) on all 10Gbps and 4/2/1Gbps ISL trunk ports
- Automatic configuration of ISL trunks including multi-hop paths between multiple switches
- Supports all multi-switch fabric topologies including stack, cascade, cascaded loop,
and mesh
- Adaptive Trunking to improve efficiency via optimal routing across multiple trunk groups
- Up to 239 switches depending on configuration
- Non-disruptive dynamic addition of ISLs to an existing trunk
- High availability with automatic path failover
|
| System Processor |
| 800 MHz PowerPC processor |
| I/O Blade Processor |
| 400 MHz PowerPC processor |
| Modular Scalability |
| Ports Per Chassis Module |
- 16 to 128 FC 4/2/1 Gbps ports
- 4 to 32 FC 10 Gbps ports
- Full Blade intermix support, maximum 8 Blades, all Blades hot-pluggable
- >475,000 user ports depending on configuration
|
| Ports Per Rack |
|
Up to 1,280 ports per 42U rack |
| Chassis Module HyperStack |
- Two BASE Model SB9200 chassis modules via 4 proprietary HyperStack cables
- Two domains
- Up to 256 Fibre Channel 4/2/1 Gbps ports
|
| Multi-switch Fabrics |
- Supports all topologies, including: stack, cascade, cascaded loop, and mesh
- Maximum 239 switches (domain IDs) depending on configuration
|
| Fabric Port Types |
- All ports are universal, auto-discovering, self configuring and can assume the following states:
- F_Port: Fabric (N_Port Id Virtualization [NPIV] support automatically enabled) with up to
255 NPIVs per port
- FL_Port: Fabric loop (public loop)
- E_Port: Switch-to-switch
|
| Administrative Port Types |
- G_Port: Generic
- GL_Port: Generic loop
|
| Port Security |
- Port binding via list of WWNs (up to 32) allowed access to a port
- ISL and port authentication via Fibre Channel Security Protocol (FC-SP) and DH-CHA P
|
| Port Statistics |
- Configuration and operational data
- Transmitted and received frame counts
- Transmitted and received error counts
|
| Media Type (Ordered Separately) |
- 8Gb I/O blade (SB9008-8G) – Hot-pluggable, industry standard 3.3 volt SFP+ transceivers (for 8 Gbps speed) or SFP transceivers (for 4 and 2 Gbps speed)
- 4Gb I/O blade (SB9004-4G) – Hot-pluggable, industry standard 3.3 volt SFPs for 4/2/1 Gbps speeds
- 10Gb I/O blade (SB9010-10G) – Hot-pluggable, indusatry-standard X2 optical transceivers or X2 copper ISL cables for 10 Gbps speed
|
| Supported SFP Transceiver Types |
- Short Wave (optical)
- Long Wave (optical)
- Active/Passive Copper (8/4/2Gb)
|
| Supported X2 Transceiver Types |
- Short Wave (optical)
- Long Wave (optical)
|
| Media Transmission Ranges (@ 10Gbps speeds) |
- Optical Media
- Short Wave: 300 m (984 ft.)
- Long Wave: 8.34 km (5.18 miles)
|
| Optical Cable Types (4Gb, 8Gb, and 10Gb) |
- 50/62.5 micron multimode fiber optic
- 9 micron single-mode fiber optic
|
| Interoperability/Certifications |
| Interoperability/Certifications |
- Fully interoperable with all QLogic SANbox switch products
- Compatible with FC-SW-2 compliant switches, including Brocade, Cisco & McDATA
- Management interoperability with leading SAN management applications
- FCIA SANmark and SNIA SMI-S certified
- SCD-3001v2a1 (E_Port)
- SCD-3002v2 (FL_Port)
- SCD-3010v1 (RSCN)
- SCD-3020v1 (Zoning)
- Certified with leading SAN hardware and software vendors.
Visit: http://www.qlogic.com/interoperability/interoperability.aspx/ for a comprehensive listing |
| Fabric Services |
| Software Releases |
- QuickTools version 7.08.XX or later
- Enterprise Fabric Suite 2007 version 7.08.XX or later
- Switch Firmware version 7.8.XX or later
|
| Ethernet Connections |
- CPU Blade: RJ-45 Ethernet Connector on each CPU Blade on back of chassis module
- Maintenance Panel: Two alternate RJ-45 Ethernet Connectors on Maintenance Panel on front
of chassis module
- IPv6 support
|
| Management Methods |
- Enterprise Fabric Suite 2007 Graphical User Interface (GUI)
- QuickTools Web Applet
- Application Programming Interface (API)
- Command Line Interface (CLI)
- GS-4 Management Server (including FDMI)
- Simple Network Management Protocol (SNMP)
- RADIUS
- File Transfer Protocol (FTP)
- Trivial File Transfer Protocol (TFTP)
- Storage Management Initiative (SMI-S)
|
| Fabric Security |
- Fabric binding via list of allowed Domain IDs and Switch WWNs
- Inter-switch management communication data path encryption
- Secure Shell (SSH) for CL
- Secure Socket Layer (SSL) for QuickTools, EFS 2007, and SMI-S
- Device, Host, and Switch Authentication
- Local security database configuration, or
- Remote authentication via a RADIUS Server
- Additional MS request authentication via FCGS4 CT authentication
- Enable/Disable in-band management of switch
|
| Registered State Change Notification (RSCN) |
- RSCNs are generated per standard (FC-GS, FCFS, FC-SW, etc.)
- Delayed to allow consolidation into single RSCN
- QLogic IO StreamGuard™ suppresses RSCNs between initiators
|
| Fabric Diagnostics |
- Optional SANdoctor software package
|
| Maintainability |
| Maintenance Strategy |
- Hot-pluggable Customer Replaceable Units (CRUs) per chassis module
- SFP & X2 transceivers
- I/O Blades (8 maximum, 3 types w/Intermix)
- CPU Blades (2 w/Model SB9200, 1 w/Model SB9100)
- Power Supply Blades (2)
- Fan Blades (2)
- Enhanced data integrity on all data paths
- Fabric Shortest Path First (FSPF) rerouting around failed links
- Integration with Simple Network Management Protocol (SNMP) managers
- Non-disruptive “hot” firmware code load and activation (NDCLA)
- Easy configuration, save, and restore
- E-Mail Call Home system initiated alarm/fault notification
|
| Maintenance Access Methods |
- Single point in-band management with autodiscovery across multiple switches via software GUI
- One out-of-band Ethernet 10/100Mb BaseT RJ-45 management port per CPU Blade,
each replicated on Maintenance Panel
- One RJ-45 serial port per CPU Blade (RJ-45 to DB-9 conversion dongle included)
- FC-GS4 Management Server
|
| Diagnostics |
- Power-On Self-Test (POST) tests all functional components except SFP and X2 transceivers
- Optional SANdoctor fabric diagnostics software
- FC Ping: verifies functional path existence between two ports
- FC Trace route: displays path information between a source and destination
- Digital Diagnostics Monitoring: displays real-time SFP, X2, and XPAK transceiver data
|
| Visual User Interface |
|
LED indicators on the Maintenance Panel, I/O Blades, CPU Blade(s), Power Supply Blades, and Fan Blades |
| Maintenance Panel (MP) |
|
Dual redundant Maintenance Panel EPROMs maintain chassis-specific information (such as WWN, SNMP System Object ID, Serial Number, Part Number, etc.), alternate Ethernet management interface ports, and LED summary status information for the switch |
| Global Services |
|
|
| Physical Characteristics |
| Enclosure Chassis Module/Blade Packaging |
- Standard Rack Mountable Chassis Module
- Includes adjustable forward/reverse Mounting Rail/Racking kit & dual power cords
- I/O Blades
- Standard and Optional I/O Blades Do NOT Include SFPs, X2 Transceivers, or Copper/Optical
Cables (which you can order separately)
- Hardware and Software License Field Upgradeable:
- SB9100 ENTRY Model to SB9200 BASE Model
- SB9200 Model to SB9200 Fault Tolerant Model
- One SB9200 BASE Model to Dual HyperStack Model
- Two SB9200 BASE Models to Dual HyperStack Model
|
| Dimensions (chassis module) |
- Width: 431 mm (17.0") 19" rack mountable
- Height: 179 mm (7.0") (4U)
- Depth: 673 mm (26.5")
|
| Weight (SB9200 chassis module maximum) |
|
|
| Power Supply/Cooling (both SB9100 & SB9200) |
- Hot-Pluggable/Dual-Redundant Power Supply Blades with Integrated Cooling Fans
- Dual 7'6" long 3-wire 16AWG power cables with IEC320 input connector
- Popular internet and country dual power cable/connector kit options available
- Hot-Pluggable/Dual-Redundant Fan Blades
- Back-to-Front and Front-to-Back Airflow Direction Models available
- 150-cfm airflow
- 1,000 watts or 3,414 BTU/hour rating per power supply
|
| Heat Output (SB9200 full data traffic maximum) |
- 2,046 BTU/hour at 128-ports 4-Gb Fibre Channel (SFPs and "local switching")
- 4,228 BTU/hour at 256-ports 4-Gb Fibre Channel HyperStack (SFPs and "local switching")
|
| Electrical Requirements |
| Operating Voltage/Frequency |
- 100 to 240 VAC auto-sensing, single phase
- 47 to 63Hz
|
| Power Source Loading (SB9200 chassis module maximum power supply rating) |
- 10 Amps at 100 VAC
- 4.2 Amps at 240 VAC
|
| Operating Load (SB9200 with no data traffic) |
- 550 Watts at 128-ports 4Gb Fibre Channel (including SFPs)
- 1,120 watts at 256-ports 4-Gb Fibre Channel HyperStack (including SFPs)
|
| Operating Load (SB9200 with full data traffic) |
- 600 Watts at 128-ports 4Gb Fibre Channel (including SFPs and "local switching")
- 1,240 watts at 256-ports 4-Gb Fibre Channel HyperStack (including SFPs and "local switching")
- Circuit Protection
- Internally fused
|
| Circuit Protection |
|
|
| Environmental Factors |
| Operating |
- Temperature: 0°C to 40°C (32° to 104°F)
- Humidity: 15% to 80% non-condensing
- Altitude: 0 to 3048m (0 to 10,000 feet)
- Vibration: IEC 68-2, 5-500 Hz, random, 0.21g RMS, 10 minutes
- Shock: IEC 68-2: 4g, 11ms, 20 repetitions
|
| Non-Operating |
- Temperature: -40°C to 70°C (-40° to 158 °F)
- Humidity: 5% to 90% non-condensing
- Altitude: 0 to 15,240m (0 to 50,000 feet)
- Vibration: IEC 68-2: 5-500 Hz, random, 2.1g RMS,10 minutes
- Shock: IEC 68-2: 30g, 13 msec, trapezoidal pulse
|
| Regulatory Certifications |
| Safety Standards |
- UL 60950-1 – UL Listed (United States)
- CAN/CSA C22.2 No. 60950-1 – cUL Listed (Canada)
- EN60950-1 (EC)
- CB Scheme-IEC 60950-1 (International)
- GOST R (Russia)
|
| Emissions Standards |
- FCC Part 15B Class A (USA)
- VCCI Class A ITE (Japan)
- ICES-003 Class A ITE (Canada)
- EN 55022 Level A (EC)
- CISPR 22, Class A (International)
- AS/NZS CISPR 22:2002 Class A (AUS/NZ)
- GOST R (Russia)
- KN22 – Class A (Korea)
|
| Environmental Standards |
|
|
| Voltage Fluctuations |
|
|
| Harmonics |
|
|
| Immunity |
|
|
| Marking |
- FCC Part 15, UL (United States)
- cUL, CUE, TUV (Canada)
- TUV , CUE, CE (EC)
- VCCI-A (Japan)
- C-Tick (AUS/NZ)
- GOST R (Russia)
- MIC (Korea)
- Exempt (Taiwan)
- UL AR/S-Mark (Argentina)
- CCC – Field replaceable unit (FRU) power supply modules (China)
|
| | | |
|
|
|
| |
QLogic Branded Product |
| |
|
Generic product configured for all environments |
| SKU |
Contents |
Warranty |
Where to Buy? |
| SB9100-16A-E |
SANbox 9100 ENTRY Model. Stackable Chassis Switch, front-to-back airflow, no SFPs, ESM Listed. Single CPU blade, one 16-port 4Gb I/O blade. Includes installed firmware, printed “Quick Start” guide, warranty card, CD containing SANbox Software management applications (CLI, QuickTools™, Enterprise Fabric Suite™ 2007 & Fabric Security Package). |
1 years* |
Click here for a list of authorized resellers and distributors. |
| SB9100-16B |
SANbox 9100 ENTRY Model Stackable Chassis Switch, back-to-front airflow, no SFPs. Single CPU blade, one 16-port 4Gb I/O blade. Includes installed firmware, printed “Quick Start” guide, warranty card, CD containing SANbox Software management applications (CLI, QuickTools™, Enterprise Fabric Suite™ 2007 & Fabric Security Package). |
1 years* |
Click here for a list of authorized resellers and distributors. |
| SB9200-32A-E |
SANbox 9200 BASE Model Stackable Chassis Switch, front-to-back airflow, no SFPs, ESM Listed. Dual CPU Blades, two 16-port 4Gb FC IO Blade. Includes installed firmware, printed "Quick Start" guide, warranty card, CD containing SANbox Software management applications (CLI, QuickTools™, Enterprise Fabric Suite™ 2007 & Fabric Security Package). |
1 years* |
Click here for a list of authorized resellers and distributors. |
| SB9200-32B |
SANbox 9200 BASE Model Stackable Chassis Switch, back-to-front airflow, no SFPs. Dual CPU Blades, two 16-port 4Gb FC IO Blade. Includes installed firmware, printed “Quick Start” guide, warranty card, CD containing SANbox Software management applications (CLI, QuickTools™, Enterprise Fabric Suite™ 2007 & Fabric Security Package). |
1 years* |
Click here for a list of authorized resellers and distributors. | |
|
|
| |
* Both SANbox 9100 ENTRY and 9200 BASE models include a 1-year hardware/firmware warranty that includes 1-year of Preferred service (remote technical phone support 7 days a week, 24 hours a day and next business day spare advanced replacement). Note: Service for additional I/O Blades (up to maximum of 8 total per chassis module) is included at the same service level at no additional charge. Additional service plan options available – see Support section. |
| |
|
| |
Related Software, Upgrades, Spares and Accessories |
| |
| SKU |
Description |
|
LK-SANDR |
Software License Key for SANdoctor™ Diagnostics, sold on a per chassis module basis. |
|
LK-9200-FT |
Fault Tolerant CPU Failover Software License Key for SANbox SB9200 BASE Model only. |
|
LK-9200-HS2 |
HyperStack™ Feature Software License Key for SB9200 BASE model only, sold per chassis module. Includes two HyperStack cables per license. |
|
SB9004-4G |
16-port 4/2/1Gb FC I/O Blade. |
|
SB9010-10G |
4-port 10Gb FC I/O Blade (X2 form factor). |
|
SB9000-CPU |
SB9100 ENTRY to SB9200 BASE Model CPU Upgrade. |
|
SB9000-APS |
SPARE: Single Power Supply Blade - Front to Back Airflow. |
|
SB9000-BPS |
SPARE: Single Power Supply Blade - Back to Front Airflow. |
|
SB9000-AFAN |
SPARE: Single Fan Blade - Front to Back Airflow. |
|
SB9000-BFAN |
SPARE: Single Fan Blade - Back to Front Airflow. |
|
SB9000-SLBL |
SPARE: IO Blade Slot Blank. |
|
SB9100-CPBL |
SPARE: CPU Blade Blank (SB9100 ENTRY Model only). |
|
SB9000-CHM |
SPARE: Chassis Module incl. Maintenance Panel. |
|
SB9000-RKIT |
SPARE: 4U Chassis Module Rail/Racking Kit for standard or reverse racking. |
|
SB9000-CPU |
SPARE: Single CPU Blade. |
| SB9008V-8G |
16-port 8/4/2Gb FC I/O Blade. |
|
HS-CABLE-25 |
SPARE: Single HyperStack™ cable - Length = 25" (635mm). |
|
X2-XPAK-COPP-78 |
X2 to XPAK 10Gb FC ISL Cable (copper) - Length = 78" (2m). |
|
X2-XPAK-COPP-18 |
X2 to XPAK 10Gb FC ISL Cable (copper) - Length = 18" (456mm). |
|
X2-COPP-18 |
X2 to X2 10Gb FC ISL Cable (copper) - Length = 18" (456mm). |
|
X2-COPP-78 |
X2 to X2 10Gb FC ISL Cable (copper) - Length = 78" (2m). |
|
X2-SW-01 |
10Gb (qty. 1) short-wave, 850nm X2 optic transceiver with LC connector. |
|
X2-LW-01 |
10Gb (qty. 1) long-wave, 1310nm X2 optic transceiver with SC connector. |
|
SFP2-SW-03 |
Optical SFPs - 2Gb (8-pack) short wave SFP connectors. |
|
SFP2-LW-01 |
Optical SFPs - 2Gb (qty. 1) long wave SFP connectors. |
|
SFP4-SW-JD4 |
Optical SFPs - 4Gb (4-pack) short wave SFP connectors. |
| CPK-9000-US |
SPARE: Country Power Kit (dual 2.5m cords): United States Non-Locking NEMA 5-15 Plug (included as standard with all SB9000s) |
| CPK-9000-USL |
Country Power Kit (dual 2.5m cords): United States Locking NEMA L6-20 Plug |
| CPK-9000-CEE |
Country Power Kit (dual 2.5m cords): Continental Europe CEE 7/7 Plug |
| CPK-9000-IEC |
Country Power Kit (dual 2.5m cords): International IEC 60309 Plug |
| CPK-9000-CH |
Country Power Kit (dual 2.5m cords): Switzerland SEV 1011 Plug |
| CPK-9000-ZAIN |
Country Power Kit (dual 2.5m cords): South Africa/India BS 546 Plug |
| CPK-9000-IL |
Country Power Kit (dual 2.5m cords): Israel SI-32 Plug |
| CPK-9000-CN |
Country Power Kit (dual 2.5m cords): China GB2099/GB1002-1 Plug |
| CPK-9000-AUNZ |
Country Power Kit (dual 2.5m cords): Australia/New Zealand AS/NZS 3112 Plug |
| CPK-9000-UKHK |
Country Power Kit (dual 2.5m cords): United Kingdom/Hong Kong BS1363/A Plug |
| CPK-9000-DK |
Country Power Kit (dual 2.5m cords): Denmark Data DK-2-5A Plug |
| CPK-9000-IT |
Country Power Kit (dual 2.5m cords): Italy CEI 23-16/VII Plug |
| CPK-9000-AR |
Country Power Kit (dual 2.5m cords): Argentina IRAM 2073.1982 Plug |
| CPK-9000-JP |
Country Power Kit (dual 2.4m cords): Japan JIS 8303 PSE Plug | |
| |
| |
|
|
|
|
|
|
|
|
|
|
Find Out More |
|
|
|
|