SANbox 9000 |
 |
|
FT & HyperStack™ & Call-Home Now Available! SANbox 9000 now becomes a true Director-class switch with the addition of the new FT CPU Failover, HyperStack and Call-Home features. Reduce TCO with the industry’s first Customer Replaceable Unit (CRU) components, smallest footprint, most flexible rack-mount options and leading power/cooling efficiency. | |
|
|
|
|
|
|
| |
| Designed to the Core™ for Open Systems |
|
Finally, there’s a new class of core switch that represents a sane alternative to quarter million dollar Director switches. The SANbox 9000 series is Designed to the Core™ for cost sensitive, business-critical, open system environments that require an ultra-high density, blazing performance, 99.999% availability, intelligent switch platform for their data center core. SANbox 9000 series represents a number of industry firsts: a stackable chassis module for simple, cost-effective scalability, a 4U chassis module for smaller footprint, the simplicity and economies of Customer Replaceable Units (CRUs) and a comprehensive set of Director-class software management tools included as standard. Best of all, pricing starts at under $100K.
The highly scalable SANbox 9000 is a stackable chassis switch with a dedicated 800Gb/s HyperStack™ connection between as many as two chassis modules. The high port count SANbox 9000 supports up to 256 ports in a dual chassis configuration. The intelligent SANbox 9000 offers in one chassis module: 8 slots for any mix of 4Gb or 10Gb Fibre Channel I/O Blades, with an 8GB FC I/O blade coming in mid-CY2008. For high availability, the SANbox 9000 features redundant, hot-swap I/O, CPU, Power Supply and Fan blades. And for comprehensive fabric management, the SANbox 9000 includes a powerful and easy-to-use suite of software tools for setting-up, monitoring, tuning, troubleshooting and servicing an unlimited number of large fabrics.
| | |
|
|
|
|
|
| |
| Ultra-High Density and Stackable Scalability |
- At twice the port density of typical 14U Director switches, the SANbox 9000 stackable chassis switch scales to 128 ports in a 4U single chassis module or up to 256 ports in an 8U dual chassis module HyperStack configuration (via backplane interconnects) – 32 ports per 1U of rack space!
- Unlike legacy Director switches, the SANbox 9000 switch provides a low cost entry point with a 16 4Gb FC port configuration. Seamlessly grow your 9000 switch in 16 port increments up to 256 ports.
- Eight I/O Blade slots per chassis module supporting multi-function technologies including:
- 4Gb or 8Gb (future) FC I/O Blade: for maximum server and storage connectivity.
- 10Gb FC I/O Blade: high-speed Inter-Switch Links (ISLs) including trunking between other Core, Distribution and Edge class switches.
- Intelligent Storage Router Modules: iSCSI for connecting low cost servers and FCIP for replicating data across a WAN.
- Broadly deployable in local, campus, distributed and remote Core/Distribution/Edge configuration topologies.
- ENTRY Model SB9100 fully upgradeable in the field to single or dual HyperStack BASE Model SB9200.
|
| Blazing Performance |
|
|
| Customer Replaceable Units (CRUs) |
- The industry’s first stackable chassis switch designed for the convenience, simplicity and economies of Customer Replaceable Units (CRUs) for key components.
- 99.999% availability with redundant, hot-pluggable CPU, Power Supply, Fan and I/O Blades, non-disruptive code load and activation (NDCLA) and non-disruptive CPU failover in support of 24x7 mission-critical operations.
|
| Low Total Cost of Ownership |
- All the benefits of a Director Class switch with revolutionary pricing that starts under $100K.
- Architected for long-term investment flexibility and protection to deliver a previously unachievable reduction in total Cost of Ownership (TCO).
- High density FC I/O Blade slots are not sacrificed for IP support. Rather, half-wide 1U SANbox 6000 Series Intelligent Storage Router (iSR) “modules” are utilized for low density/low cost iSCSI and FCIP ports (see http://www.qlogic.com/Products/SAN_products_storagerouters.aspx).
- For SAN administrators that have invested in multi-vendor fabrics, the SANbox 9000 is interoperable with all FC-SW-2 compliant Fibre Channel Director, Edge class switches and popular servers, storage and networking products from major manufacturers.
- Minimize management costs with easy-to-use and comprehensive Command Line Interface (CLI), QuickTools™ embedded web interface, and Enterprise Fabric Suite™ 2007 software tools included with each SANbox 9000 switch.
- Take a significant bite out of your operating costs as a result of the SANbox 9000's low power and cooling requirements, minimal footprint, and all-encompassing service plans.
|
| | | |
|
|
|
|
|
| |
|
Fabric Specifications |
| Fibre Channel Protocols |
- Physical Interface (FC-PI-3)
- Line Services (FC-LS)
- Framing & Signaling (FC-FS-2)
- Generic Services (FC-GS/FC-GS-2/FC-GS-3/FCGS- 4/FC-GS-5)
- Switch Fabric (FC-SW-2/FC-SW-3/FC-SW-4), except for enhanced zoning
- Arbitrated Loop Rev. 4.6 (FC-AL)
- Arbitrated Loop-2 Rev. 7.0 (FC-AL-2)
- Fibre Loop Attachment (FC-FLA)
- Tape Technical Report (FC-Tape)
- Virtual Interface Architecture Mapping (FC-VI)
- Fabric Element MIB Specification (RFC 2837)
- Fibre Alliance MIB Specification (Version 4.0)
- Methodologies for Interconnects (FC-MI-2)
- Device Attach (FC-DA)
- Security Protocols (FC-SP)
|
| Fibre Channel Classes of Service |
|
Class 2, Class 3, and Class F (inter-switch frames) connectionless Fibre Channel protocol support |
| Modes of Operation |
- Fabric
- Public loop
- Broadcast
|
| Performance Features |
| Fabric Port Speed |
- FC4G16 I/O Blades @ 1.0625, 2.2125, & 4.250 Gbps
- Auto-sensing of 1, 2, & 4 Gbps port speeds
- Optionally programmable to fixed port speed
- FC10G4 I/O Blades @ 12.75 Gbps
|
| FC Fabric Latency (Best Case) |
- <0.6µsec @ 1-Gbps
- <0.4µsec @ 2-Gbps
- <0.3µsec @ 4-Gbps
- <0.2µsec @ 10-Gbps
- Cut-through routing
|
| FC Fabric Point-to-Point Bandwidth |
- 212MB/s Full-Duplex on 1Gb ports
- 424MB/s Full-Duplex on 2Gb ports
- 850MB/s Full-Duplex on 4Gb ports
- 2550 MB/s Full-Duplex on 10Gb ports
|
| FC Fabric Aggregate Bandwidth |
- SANbox 9100 Model – 408 Gbps, full duplex
- SANbox 9200 Model – 816 Gbps, full duplex
- 2X SANbox 9200 Model HyperStack – 1.632 T bps, full duplex
- Non-blocking HyperStack™ architecture
|
| Maximum Frame Sizes |
- 2148 bytes (2112 byte payload)
- In-order delivery assured within OX-ID
|
| Per-port Buffering |
- ASIC-embedded memory (non-shared)
- Each port has a guaranteed 16-credit zero wait state buffer for full performance up to
13km @ 2Gb and 2Km @ 10Gb
- Buffer credit donor support via software GUI wizard to extend distance with full performance
|
| Inter-Switch Link (ISL) Trunking |
- Supports aggregation of up to 128 ISLs in one or more trunks between multiple switches in
any port speed combination and across multiple I/O Blades
- 10Gb recommended to maximize number of usable 4/2/1Gb Server/Storage ports on
both SANbox 5000 Series and 9000 Series switches
- Switch-On-Exchange (SOE) mode for dynamic ISL trunk load balancing to maximize throughput
- Assured in-order delivery of frames in all multi-switch and multi-ISL trunked configurations
- Adaptive Trunking to improve efficiency via optimal routing across multiple trunk groups
- Intelligent Path Selection (IPS) on all 10Gbps and 4/2/1Gbps ISL trunk ports
- Automatic configuration of ISL trunks including multi-hop paths between multiple switches
- Supports all multi-switch fabric topologies including stack, cascade, cascaded loop,
and mesh
- Adaptive Trunking to improve efficiency via optimal routing across multiple trunk groups
- Up to 239 switches depending on configuration
- Non-disruptive dynamic addition of ISLs to an existing trunk
- High availability with automatic path failover
- Interop mode support: McDATA Open Mode, Brocade interopMode 1, Cisco Open Mode
|
| System Processor |
| 800 MHz PowerPC processor |
| I/O Blade Processor |
| 400 MHz PowerPC processor |
| Modular Scalability |
| Ports Per Chassis Module |
- 16 to 128 FC 4/2/1 Gbps ports
- 4 to 32 FC 10 Gbps ports
- Full Blade intermix support, maximum 8 Blades, all Blades hot-pluggable
- >475,000 user ports depending on configuration
|
| Ports Per Rack |
|
Up to 1,280 ports per 42U rack |
| Chassis Module HyperStack |
- Two BASE Model SB9200 chassis modules via 4 proprietary HyperStack cables
- Two domains
- Up to 256 Fibre Channel 4/2/1 Gbps ports
|
| Multi-switch Fabrics |
- Supports all topologies, including: stack, cascade, cascaded loop, and mesh
- Maximum 239 switches (domain IDs) depending on configuration
|
| Fabric Port Types |
- All ports are universal, auto-discovering, self configuring and can assume the following states:
- F_Port: Fabric (N_Port Id Virtualization [NPIV] support automatically enabled) with up to
255 NPIVs per port
- FL_Port: Fabric loop (public loop)
- E_Port: Switch-to-switch
|
| Administrative Port Types |
- G_Port: Generic
- GL_Port: Generic loop
|
| Port Security |
- Port binding via list of WWNs (up to 32) allowed access to a port
- ISL and port authentication via Fibre Channel Security Protocol (FC-SP) and DH-CHA P
|
| Port Statistics |
- Configuration and operational data
- Transmitted and received frame counts
- Transmitted and received error counts
|
| Media Type (Ordered Separately) |
- Hot-pluggable, industry-standard 3.3 volt SFPs (Small Form Pluggable) for 4/2/1Gb ports
- Hot-pluggable, industry-standard X2 optical transceivers or X2 copper ISL cables for 10Gb ports
|
| Supported SFP Transceiver Types |
- Short Wave (optical)
- Long Wave (optical)
- Active/Passive Copper (4/2Gb)
|
| Supported X2 Transceiver Types |
- Short Wave (optical)
- Long Wave (optical)
|
| Media Transmission Ranges (@ 10Gbps speeds) |
- Optical Media
- Short Wave: 300 m (984 ft.)
- Long Wave: 8.34 km (5.18 miles)
|
| Optical Cable Types (4Gb & 10Gb) |
- 50/62.5 micron multimode fiber optic
- 9 micron single-mode fiber optic
|
| Interoperability/Certifications |
| Interoperability/Certifications |
- Fully interoperable with all QLogic SANbox switch products
- Compatible with FC-SW-2 compliant switches, including Brocade, Cisco & McDATA
- Management interoperability with leading SAN management applications
- FCIA SANmark and SNIA SMI-S certified
- SCD-3001v2a1 (E_Port)
- SCD-3002v2 (FL_Port)
- SCD-3010v1 (RSCN)
- SCD-3020v1 (Zoning)
- Certified with leading SAN hardware and software vendors.
Visit: http://www.qlogic.com/interoperability/interoperability.aspx/ for a comprehensive listing |
| Fabric Services |
| Software Releases |
- QuickTools version 6.08.02 or later
- Enterprise Fabric Suite 2007 version 6.08.02 or later
- Switch Firmware version 6.8.03 or later
|
| Ethernet Connections |
- CPU Blade: RJ-45 Ethernet Connector on each CPU Blade on back of chassis module
- Maintenance Panel: Two alternate RJ-45 Ethernet Connectors on Maintenance Panel on front
of chassis module |
| Management Methods |
- Enterprise Fabric Suite 2007 Graphical User Interface (GUI)
- QuickTools Web Applet
- Application Programming Interface (API)
- Command Line Interface (CLI)
- GS-4 Management Server (including FDMI)
- Simple Network Management Protocol (SNMP)
- RADIUS
- File Transfer Protocol (FTP)
- Trivial File Transfer Protocol (TFTP)
- Storage Management Initiative (SMI-S)
|
| Fabric Security |
- Fabric binding via list of allowed Domain IDs and Switch WWNs
- Inter-switch management communication data path encryption
- Secure Shell (SSH) for CL
- Secure Socket Layer (SSL) for QuickTools, EFS 2007, and SMI-S
- Device, Host, and Switch Authentication
- Local security database configuration, or
- Remote authentication via a RADIUS Server
- Additional MS request authentication via FCGS4 CT authentication
- Enable/Disable in-band management of switch
|
| Registered State Change Notification (RSCN) |
- RSCNs are generated per standard (FC-GS, FCFS, FC-SW, etc.)
- Delayed to allow consolidation into single RSCN
- QLogic IO StreamGuard™ suppresses RSCNs between initiators
|
| Fabric Diagnostics |
- Optional SANdoctor software package
|
| Maintainability |
| Maintenance Strategy |
- Hot-pluggable Customer Replaceable Units (CRUs) per chassis module
- SFP & X2 transceivers
- I/O Blades (8 maximum, 3 types w/Intermix)
- CPU Blades (2 w/Model SB9200, 1 w/Model SB9100)
- Power Supply Blades (2)
- Fan Blades (2)
- Enhanced data integrity on all data paths
- Fabric Shortest Path First (FSPF) rerouting around failed links
- Integration with Simple Network Management Protocol (SNMP) managers
- Non-disruptive “hot” firmware code load and activation (NDCLA)
- Easy configuration, save, and restore
- E-Mail Call Home system initiated alarm/fault notification
|
| Maintenance Access Methods |
- Single point in-band management with autodiscovery across multiple switches via software GUI
- One out-of-band Ethernet 10/100Mb BaseT RJ-45 management port per CPU Blade,
each replicated on Maintenance Panel
- One RJ-45 serial port per CPU Blade (RJ-45 to DB-9 conversion dongle included)
- FC-GS4 Management Server
|
| Diagnostics |
- Power-On Self-Test (POST) tests all functional components except SFP and X2 transceivers
- Optional SANdoctor fabric diagnostics software
- FC Ping: verifies functional path existence between two ports
- FC Trace route: displays path information between a source and destination
- Digital Diagnostics Monitoring: displays real-time SFP, X2, and XPAK transceiver data
|
| Visual User Interface |
|
LED indicators on the Maintenance Panel, I/O Blades, CPU Blade(s), Power Supply Blades, and Fan Blades |
| Maintenance Panel (MP) |
|
Dual redundant Maintenance Panel EPROMs maintain chassis-specific information (such as WWN, SNMP System Object ID, Serial Number, Part Number, etc.), alternate Ethernet management interface ports, and LED summary status information for the switch |
| Global Services |
|
|
| Physical Characteristics |
| Enclosure Chassis Module/Blade Packaging |
- Standard Rack Mountable Chassis Module
- Includes adjustable forward/reverse Mounting Rail/Racking kit & dual power cords
- I/O Blades
- Standard and Optional I/O Blades Do NOT Include SFPs, X2 Transceivers, or Copper/Optical
Cables (which you can order separately)
- Hardware and Software License Field Upgradeable:
- SB9100 ENTRY Model to SB9200 BASE Model
- SB9200 Model to SB9200 Fault Tolerant Model
- One SB9200 BASE Model to Dual HyperStack Model
- Two SB9200 BASE Models to Dual HyperStack Model
|
| Dimensions (chassis module) |
- Width: 431 mm (17.0") 19" rack mountable
- Height: 179 mm (7.0") (4U)
- Depth: 673 mm (26.5")
|
| Weight (SB9200 chassis module maximum) |
|
|
| Power Supply/Cooling (both SB9100 & SB9200) |
- Hot-Pluggable/Dual-Redundant Power Supply Blades with Integrated Cooling Fans
- Dual 7'6" long 3-wire 16AWG power cables with IEC320 input connector
- Popular internet and country dual power cable/connector kit options available
- Hot-Pluggable/Dual-Redundant Fan Blades
- Back-to-Front and Front-to-Back Airflow Direction Models available
- 150-cfm airflow
- 1,000 watts or 3,414 BTU/hour rating per power supply
|
| Heat Output (SB9200 full data traffic maximum) |
- 2,046 BTU/hour at 128-ports 4-Gb Fibre Channel (SFPs and "local switching")
- 4,228 BTU/hour at 256-ports 4-Gb Fibre Channel HyperStack (SFPs and "local switching")
|
| Electrical Requirements |
| Operating Voltage/Frequency |
- 100 to 240 VAC auto-sensing, single phase
- 47 to 63Hz
|
| Power Source Loading (SB9200 chassis module maximum power supply rating) |
- 10 Amps at 100 VAC
- 4.2 Amps at 240 VAC
|
| Operating Load (SB9200 with no data traffic) |
- 550 Watts at 128-ports 4Gb Fibre Channel (including SFPs)
- 1,120 watts at 256-ports 4-Gb Fibre Channel HyperStack (including SFPs)
|
| Operating Load (SB9200 with full data traffic) |
- 600 Watts at 128-ports 4Gb Fibre Channel (including SFPs and "local switching")
- 1,240 watts at 256-ports 4-Gb Fibre Channel HyperStack (including SFPs and "local switching")
- Circuit Protection
- Internally fused
|
| Circuit Protection |
|
|
| Environmental Factors |
| Operating |
- Temperature: 0°C to 40°C (32° to 104°F)
- Humidity: 15% to 80% non-condensing
- Altitude: 0 to 3048m (0 to 10,000 feet)
- Vibration: IEC 68-2, 5-500 Hz, random, 0.21g RMS, 10 minutes
- Shock: IEC 68-2: 4g, 11ms, 20 repetitions
|
| Non-Operating |
- Temperature: -40°C to 70°C (-40° to 158 °F)
- Humidity: 5% to 90% non-condensing
- Altitude: 0 to 15,240m (0 to 50,000 feet)
- Vibration: IEC 68-2: 5-500 Hz, random, 2.1g RMS,10 minutes
- Shock: IEC 68-2: 30g, 13 msec, trapezoidal pulse
|
| Regulatory Certifications |
| Safety Standards |
- UL 60950-1 – UL Listed (United States)
- CAN/CSA C22.2 No. 60950-1 – cUL Listed (Canada)
- EN60950-1 (EC)
- CB Scheme-IEC 60950-1 (International)
- GOST R (Russia)
|
| Emissions Standards |
- FCC Part 15B Class A (USA)
- VCCI Class A ITE (Japan)
- ICES-003 Class A ITE (Canada)
- EN 55022 Level A (EC)
- CISPR 22, Class A (International)
- AS/NZS CISPR 22:2002 Class A (AUS/NZ)
- GOST R (Russia)
- KN22 – Class A (Korea)
|
| Environmental Standards |
|
|
| Voltage Fluctuations |
|
|
| Harmonics |
|
|
| Immunity |
|
|
| Marking |
- FCC Part 15, UL (United States)
- cUL, CUE, TUV (Canada)
- TUV , CUE, CE (EC)
- VCCI-A (Japan)
- C-Tick (AUS/NZ)
- GOST R (Russia)
- MIC (Korea)
- Exempt (Taiwan)
- UL AR/S-Mark (Argentina)
- CCC – Field replaceable unit (FRU) power supply modules (China)
|
| | | |
|
|
|
| |
QLogic Branded Product |
| |
|
Generic product configured for all environments |
| SKU |
Contents |
Warranty |
Where to Buy? |
| SB9100-16A-E |
SANbox 9100 ENTRY Model. Stackable Chassis Switch, front-to-back airflow, no SFPs, ESM Listed. Single CPU blade, one 16-port 4Gb I/O blade. Includes installed firmware, printed “Quick Start” guide, warranty card, CD containing SANbox Software management applications (CLI, QuickTools™, Enterprise Fabric Suite™ 2007 & Fabric Security Package). |
1 years* |
Click here for a list of authorized resellers and distributors. |
| SB9100-16B |
SANbox 9100 ENTRY Model Stackable Chassis Switch, back-to-front airflow, no SFPs. Single CPU blade, one 16-port 4Gb I/O blade. Includes installed firmware, printed “Quick Start” guide, warranty card, CD containing SANbox Software management applications (CLI, QuickTools™, Enterprise Fabric Suite™ 2007 & Fabric Security Package). |
1 years* |
Click here for a list of authorized resellers and distributors. |
| SB9200-32A-E |
SANbox 9200 BASE Model Stackable Chassis Switch, front-to-back airflow, no SFPs, ESM Listed. Dual CPU Blades, two 16-port 4Gb FC IO Blade. Includes installed firmware, printed "Quick Start" guide, warranty card, CD containing SANbox Software management applications (CLI, QuickTools™, Enterprise Fabric Suite™ 2007 & Fabric Security Package). |
1 years* |
Click here for a list of authorized resellers and distributors. |
| SB9200-32B |
SANbox 9200 BASE Model Stackable Chassis Switch, back-to-front airflow, no SFPs. Dual CPU Blades, two 16-port 4Gb FC IO Blade. Includes installed firmware, printed “Quick Start” guide, warranty card, CD containing SANbox Software management applications (CLI, QuickTools™, Enterprise Fabric Suite™ 2007 & Fabric Security Package). |
1 years* |
Click here for a list of authorized resellers and distributors. | |
|
|
| |
* Both SANbox 9100 ENTRY and 9200 BASE models include a 1-year hardware/firmware warranty that includes 1-year of Preferred service (remote technical phone support 7 days a week, 24 hours a day and next business day spare advanced replacement). Note: Service for additional I/O Blades (up to maximum of 8 total per chassis module) is included at the same service level at no additional charge. Additional service plan options available – see Support section. |
| |
|
| |
Related Software, Upgrades, Spares and Accessories |
| |
| SKU |
Description |
|
LK-SANDR |
Software License Key for SANdoctor™ Diagnostics, sold on a per chassis module basis. |
|
LK-9200-FT |
Fault Tolerant CPU Failover Software License Key for SANbox SB9200 BASE Model only. |
|
LK-9200-HS2 |
HyperStack™ Feature Software License Key for SB9200 BASE model only, sold per chassis module. Includes two HyperStack cables per license. |
|
SB9004-4G |
16-port 4/2/1Gb FC I/O Blade. |
|
SB9010-10G |
4-port 10Gb FC I/O Blade (X2 form factor). |
|
SB9000-CPU |
SB9100 ENTRY to SB9200 BASE Model CPU Upgrade. |
|
SB9000-APS |
SPARE: Single Power Supply Blade - Front to Back Airflow. |
|
SB9000-BPS |
SPARE: Single Power Supply Blade - Back to Front Airflow. |
|
SB9000-AFAN |
SPARE: Single Fan Blade - Front to Back Airflow. |
|
SB9000-BFAN |
SPARE: Single Fan Blade - Back to Front Airflow. |
|
SB9000-SLBL |
SPARE: IO Blade Slot Blank. |
|
SB9100-CPBL |
SPARE: CPU Blade Blank (SB9100 ENTRY Model only). |
|
SB9000-CHM |
SPARE: Chassis Module incl. Maintenance Panel. |
|
SB9000-RKIT |
SPARE: 4U Chassis Module Rail/Racking Kit for standard or reverse racking. |
|
SB9000-CPU |
SPARE: Single CPU Blade. |
|
HS-CABLE-25 |
SPARE: Single HyperStack™ cable - Length = 25" (635mm). |
|
X2-XPAK-COPP-78 |
X2 to XPAK 10Gb FC ISL Cable (copper) - Length = 78" (2m). |
|
X2-XPAK-COPP-18 |
X2 to XPAK 10Gb FC ISL Cable (copper) - Length = 18" (456mm). |
|
X2-COPP-18 |
X2 to X2 10Gb FC ISL Cable (copper) - Length = 18" (456mm). |
|
X2-COPP-78 |
X2 to X2 10Gb FC ISL Cable (copper) - Length = 78" (2m). |
|
X2-SW-01 |
10Gb (qty. 1) short-wave, 850nm X2 optic transceiver with LC connector. |
|
X2-LW-01 |
10Gb (qty. 1) long-wave, 1310nm X2 optic transceiver with SC connector. |
|
SFP2-SW-03 |
Optical SFPs - 2Gb (8-pack) short wave SFP connectors. |
|
SFP2-LW-01 |
Optical SFPs - 2Gb (qty. 1) long wave SFP connectors. |
|
SFP4-SW-JD4 |
Optical SFPs - 4Gb (4-pack) short wave SFP connectors. |
| CPK-9000-US |
SPARE: Country Power Kit (dual 2.5m cords): United States Non-Locking NEMA 5-15 Plug (included as standard with all SB9000s) |
| CPK-9000-USL |
Country Power Kit (dual 2.5m cords): United States Locking NEMA L6-20 Plug |
| CPK-9000-CEE |
Country Power Kit (dual 2.5m cords): Continental Europe CEE 7/7 Plug |
| CPK-9000-IEC |
Country Power Kit (dual 2.5m cords): International IEC 60309 Plug |
| CPK-9000-CH |
Country Power Kit (dual 2.5m cords): Switzerland SEV 1011 Plug |
| CPK-9000-ZAIN |
Country Power Kit (dual 2.5m cords): South Africa/India BS 546 Plug |
| CPK-9000-IL |
Country Power Kit (dual 2.5m cords): Israel SI-32 Plug |
| CPK-9000-CN |
Country Power Kit (dual 2.5m cords): China GB2099/GB1002-1 Plug |
| CPK-9000-AUNZ |
Country Power Kit (dual 2.5m cords): Australia/New Zealand AS/NZS 3112 Plug |
| CPK-9000-UKHK |
Country Power Kit (dual 2.5m cords): United Kingdom/Hong Kong BS1363/A Plug |
| CPK-9000-DK |
Country Power Kit (dual 2.5m cords): Denmark Data DK-2-5A Plug |
| CPK-9000-IT |
Country Power Kit (dual 2.5m cords): Italy CEI 23-16/VII Plug |
| CPK-9000-AR |
Country Power Kit (dual 2.5m cords): Argentina IRAM 2073.1982 Plug |
| CPK-9000-JP |
Country Power Kit (dual 2.4m cords): Japan JIS 8303 PSE Plug | |
| |
| |
|
|
|
|
|
|
|
|
|
|
Find Out More |
|
|
|
|